HP Insight Diagnostics Version 10.60.2109A (x86_64)
Computer Name: smartstart

Diagnosis Log


Diagnosis Log is empty

Test Log


Passed - Denotes passed tests
Warning - Denotes tests that passed with warnings
Failed - Denotes failed tests
Device, TestNumber of Times TestedFailed CountTest TimeLast Completion 
PCI Bus 0 - Read Test10
30 ms
10/31/2021 10:35:08 PM
Passed
PCI Bus 1 - Read Test10
20 ms
10/31/2021 10:35:08 PM
Passed
PCI Bus 2 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 3 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 4 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 5 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 11 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 62 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
PCI Bus 63 - Read Test10
20 ms
10/31/2021 10:35:09 PM
Passed
Serial Port 0 - Register Test10
< 1 ms
10/31/2021 10:35:09 PM
Passed
Processor Package 1 - Floating Point Operations Test10
1 ms
10/31/2021 10:35:09 PM
Passed
Processor Package 2 - Floating Point Operations Test10
1 ms
10/31/2021 10:35:09 PM
Passed
Hard Drive 1, Storage Controller in Slot 0 - Drive Temperature Test10
14 ms
10/31/2021 10:35:09 PM
Passed
Hard Drive 2, Storage Controller in Slot 0 - Drive Temperature Test10
14 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 3, Storage Controller in Slot 0 - Drive Temperature Test10
14 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 4, Storage Controller in Slot 0 - Drive Temperature Test10
16 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 5, Storage Controller in Slot 0 - Drive Temperature Test10
192 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 6, Storage Controller in Slot 0 - Drive Temperature Test10
14 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 7, Storage Controller in Slot 0 - Drive Temperature Test10
16 ms
10/31/2021 10:35:10 PM
Passed
Hard Drive 8, Storage Controller in Slot 0 - Drive Temperature Test10
14 ms
10/31/2021 10:35:10 PM
Passed
Processor Package 1 - 64-bit Operations Test10
6 ms
10/31/2021 10:35:11 PM
Passed
Processor Package 2 - 64-bit Operations Test10
3 ms
10/31/2021 10:35:11 PM
Passed
Processor Package 1 - Temperature Check Test10
21 ms
10/31/2021 10:35:12 PM
Passed
Processor Package 2 - Temperature Check Test10
4 ms
10/31/2021 10:35:12 PM
Passed
Hard Drive 5, Storage Controller in Slot 0 - Scattered Read Test10
00:00:14
10/31/2021 10:35:26 PM
Passed
Hard Drive 2, Storage Controller in Slot 0 - Scattered Read Test10
00:00:31
10/31/2021 10:35:42 PM
Passed
Hard Drive 1, Storage Controller in Slot 0 - Scattered Read Test10
00:00:31
10/31/2021 10:35:43 PM
Passed
Hard Drive 6, Storage Controller in Slot 0 - Scattered Read Test10
00:00:31
10/31/2021 10:35:43 PM
Passed
Hard Drive 7, Storage Controller in Slot 0 - Scattered Read Test10
00:00:31
10/31/2021 10:35:43 PM
Passed
Hard Drive 3, Storage Controller in Slot 0 - Scattered Read Test10
00:00:32
10/31/2021 10:35:43 PM
Passed
Hard Drive 8, Storage Controller in Slot 0 - Scattered Read Test10
00:00:32
10/31/2021 10:35:44 PM
Passed
Hard Drive 4, Storage Controller in Slot 0 - Scattered Read Test10
00:00:34
10/31/2021 10:35:45 PM
Passed
Hard Drive 2, Storage Controller in Slot 0 - Short Background Self Test10
00:00:30
10/31/2021 10:36:13 PM
Passed
Hard Drive 6, Storage Controller in Slot 0 - Short Background Self Test10
00:00:30
10/31/2021 10:36:14 PM
Passed
Hard Drive 2, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:14 PM
Passed
Hard Drive 7, Storage Controller in Slot 0 - Short Background Self Test10
00:00:30
10/31/2021 10:36:14 PM
Passed
Hard Drive 3, Storage Controller in Slot 0 - Short Background Self Test10
00:00:30
10/31/2021 10:36:14 PM
Passed
Hard Drive 6, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:15 PM
Passed
Hard Drive 3, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:15 PM
Passed
Hard Drive 7, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:15 PM
Passed
Hard Drive 1, Storage Controller in Slot 0 - Short Background Self Test10
00:00:35
10/31/2021 10:36:19 PM
Passed
Hard Drive 1, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:19 PM
Passed
Hard Drive 8, Storage Controller in Slot 0 - Short Background Self Test10
00:00:35
10/31/2021 10:36:20 PM
Passed
Hard Drive 8, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:20 PM
Passed
Hard Drive 4, Storage Controller in Slot 0 - Short Background Self Test10
00:00:35
10/31/2021 10:36:21 PM
Passed
Hard Drive 4, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
13 ms
10/31/2021 10:36:22 PM
Passed
Hard Drive 5, Storage Controller in Slot 0 - Short Background Self Test11
00:03:15
10/31/2021 10:38:42 PM
Failed
Hard Drive 5, Storage Controller in Slot 0 - S.M.A.R.T. Error Test10
192 ms
10/31/2021 10:38:43 PM
Passed
Serial Port 0 - Internal Loopback Test10
20 ms
10/31/2021 10:38:43 PM
Passed
Fan Slot 1 - Fan Status Test10
0:00:05
10/31/2021 10:38:49 PM
Passed
Fan Slot 2 - Fan Status Test10
0:00:05
10/31/2021 10:38:54 PM
Passed
Fan Slot 3 - Fan Status Test10
0:00:05
10/31/2021 10:39:00 PM
Passed
Fan Slot 4 - Fan Status Test10
0:00:05
10/31/2021 10:39:05 PM
Passed
Fan Slot 5 - Fan Status Test10
0:00:05
10/31/2021 10:39:11 PM
Passed
Fan Slot 6 - Fan Status Test10
0:00:05
10/31/2021 10:39:16 PM
Passed
Power Supply 1 - Power Supply Status Test10
0:00:05
10/31/2021 10:39:31 PM
Passed
Power Supply 2 - Power Supply Status Test10
0:00:05
10/31/2021 10:39:37 PM
Passed
Total memory - Address Test10
0:00:19
10/31/2021 10:39:56 PM
Passed
Total memory - Read test10
0:00:59
10/31/2021 10:40:56 PM
Passed
Total memory - March test10
0:01:55
10/31/2021 10:42:52 PM
Passed
Total memory - Noise test10
0:00:54
10/31/2021 10:43:47 PM
Passed
Total memory - Walk test10
0:00:19
10/31/2021 10:44:06 PM
Passed

Error Log


Device, Test:Hard Drive 5, Storage Controller in Slot 0 - Short Background Self TestFailed Count:1Error Code:F70
Description:
The self test has failed.

Recommended Repair:
Read the controller and drive documentation to check if the drive supports this feature. Do not run the test if the drive SelfTest is not supported. If the drive SelfTest is supported, replace the drive or controller.
Device Location:
The hard drive at connector 2I, enclosure number 1, enclosure bay 5. Connected to: HP P410i HP Smart Array Controller, Slot 0.
Device, Test:Hard Drive 5, Storage Controller in Slot 0 - Short Background Self TestFailed Count:1Error Code:F70
Description:
The self test has failed.
Test Code:1 Test Number:0 Address Of First Failure:281311173 Sense Key:3 ASC:17 ASCQ:0
Recommended Repair:
Read the controller and drive documentation to check if the drive supports this feature. Do not run the test if the drive SelfTest is not supported. If the drive SelfTest is supported, replace the drive or controller.
Device Location:
The hard drive at connector 2I, enclosure number 1, enclosure bay 5. Connected to: HP P410i HP Smart Array Controller, Slot 0.

Integrated Management Log


SeverityClassLast UpdateInitial UpdateCountDescription
InformationalMaintenance10/31/2021 22:3410/31/2021 22:341Maintenance note: IML cleared by Insight Diagnostics

System Event Log


System Event Log is empty